PIV Analysis of Inner Flow Field in 90° Bending Duct of Circular-Section with Fore-End Valve |
XIE Long-1, JIN Si-Yu-1, 2 , YU Jian-Guo-1, WANG Yu-Zhang-1 |
(1. Key Laboratory for Power Machinery and Engineering of Ministry of Education, Shanghai Jiaotong University, Shanghai 200240, China;
2. Shanghai Marine Equipment Research Institute, Shanghai 200031, China) |
|
|
Abstract Through the established recirculation water channel, the inner flow field in 90° bending duct of circular-section with a fore-end valve was measured by particle image velocimetry (PIV). Characteristics of the flow were obtained through correlation analysis of the massive consecutive high-resolution transient velocity maps, including time-averaged velocity field, streamline pattern and vorticity distributions. Through comparative analysis of the time-averaged velocity field: it is concluded that there exist apparent high-speed and lowspeed regions in the bend part; a vortex emerges on specific conditions; the features of the flow field vary considerably along with the diversity of valve opening magnitude, flow rate and section location.
|
Received: 02 March 2011
Published: 30 September 2011
|
|
|
|
|
No related articles found! |
|
|
|
|