Photon-counting CT in liver disease: applications and advances

  • LI Weixia ,
  • YAN Fuhua
Expand
  • Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine;Faculty of Medical Imaging Technology, College of Health Science and Technology, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China

Received date: 2025-01-02

  Accepted date: 2025-03-09

  Online published: 2025-07-11

Abstract

Photon-counting computed tomography (PCCT) represents a significant technological breakthrough in the field of CT imaging in recent years. This innovative technology utilizes novel semiconductor detectors to directly detect and count individual X-ray photons, enabling high-precision multi-energy data acquisition. Compared with traditional energy-integrating detector CT (EID-CT), PCCT offers significant technical advantages, including ultra-high spatial resolution (with a minimum detector pixel size of 0.15×0.18 mm), improved contrast-to-noise ratio (CNR increase of 15%-45%), and substantial radiation dose reduction (20%-90%). Moreover, PCCT can generate standardized CT value images, ensu-ring stable and reproducible quantitative measurements suitable for tissue composition analysis. With its ability to acquire data across multiple energy bins, PCCT achieves true multi-energy spectral imaging. In liver diseases, PCCT enables non-enhanced quantification of hepatic fat and iron content, with 70 keV standardized CT values showing a strong correlation with MRI-derived proton density fat fraction (PDFF). During contrast-enhanced scans, PCCT significantly improves the detection rate and lesion margin delineation of hypovascular tumors and allows accurate enhancement quantification through iodine maps. Additionally, PCCT enables ultra-low-dose, one-stop imaging that simultaneously provides functional hemodynamic parameters of hepatic microcirculation and high-quality multiphasic monoenergetic CT images for clinical diagnosis and preoperative planning—without the need for additional contrast medium or supplementary triphasic scans. This dual benefit of low radiation and contrast dose supports its clinical utility in liver imaging. This review focuses on recent advances in the application of PCCT in the diagnosis and treatment of diffuse and neoplastic liver diseases, aiming to provide theoretical foundations and practical insights for its broader implementation in precision hepatology.

Cite this article

LI Weixia , YAN Fuhua . Photon-counting CT in liver disease: applications and advances[J]. Journal of Diagnostics Concepts & Practice, 2025 , 24(02) : 118 -124 . DOI: 10.16150/j.1671-2870.2025.02.002

References

[1] RAJIAH P, PARAKH A, KAY F, et al. Update on multienergy CT: physics, rinciples, and applications[J]. Radiographics,2020,40(5):1284-1308.
[2] ESQUIVEL A, FERRERO A, MILETO A, et al. Photon-counting detector CT: key points radiologists should know[J]. Korean J Radiol,2022,23(9):854-865.
[3] SCHWARTZ F R, SODICKSON A D, PICKHARDT P J, et al. Photon-counting CT: Technology, current and potential future clinical applications, and overview of approved systems and those in various stages of research and deve-lopment[J]. Radiology,2025,314(3):e240662.
[4] LEE C L, HONG K J, KIM N, et al. Feasibility study of portable multi-energy computed tomography with photon-counting detector for preclinical and clinical applications[J]. Sci Rep,2021,11(1):22731.
[5] WILLEMINK M J, PERSSON M, POURMORTEZA A, et al. Photon-counting CT:technical principles and clinical prospects[J]. Radiology,2018,289(2):293-312.
[6] LENG S, BRUESEWITZ M, TAO S, et al. Photon-counting detector CT: system design and clinical applications of an emerging technology[J]. Radiographics,2019,39(3):729-743.
[7] KREISLER B. Photon counting detectors:concept,technical challenges,and clinical outlook[J]. Eur J Radiol,2022,149:110229.
[8] SYMONS R, POURMORTEZA A, SANDFORT V, et al. Feasibility of dose-reduced chest CT with photon-counting detectors:initial results in humans[J]. Radiology,2017,285(3):980-989.
[9] SCHWARTZ F R, RIA F, MCCABE C, et al. Image qua-lity of photon counting and energy integrating chest CT - Prospective head-to-head comparison on same patients[J]. Eur J Radiol,2023,166,111014.
[10] 中华医学会放射学分会,《中华放射学杂志》光子计数CT临床应用协作组. 光子计数CT临床应用专家共识[J]. 中华放射学杂志,2025,59(4):364-383.
  Chinese Society of Radiology Chinese Medical Association, Chinese Journal of Radiology Photon-Counting CT Clinical Application Collaborative Group. Expert consensus on clinical application of photon-counting CT[J]. Chin J Radiol,2025,59(4):364-383.
[11] HUFLAGE H, KUNZ A S, PATZER T S, et al. Submillisievert abdominal photon-counting CT versus energy-integrating detector CT for urinary calculi detection:impact on diagnostic confidence[J]. Radiology,2024,312(1):e232453.
[12] LEE D, ZHAN X, TAI W Y, et al. Improving model-data mismatch for photon-counting detector model using global and local model parameters[J]. Med Phys,2024,51(2):964-977.
[13] JUNGBLUT L, BLüTHGEN C, POLACIN M, et al. First performance evaluation of an artificial intelligence-based computer-aided detection system for pulmonary nodule evaluation in dual-source photon-counting detector CT at different low-dose levels[J]. Invest Radiol,2022,57(2):108-114.
[14] ZHAN X, ZHANG R, NIU X, et al. Comprehensive evalua-tions of a prototype full field-of-view photon counting CT system through phantom studies[J]. Phys Med Biol,2023,68(17).
[15] LAMBERT J W, SUN Y, STILLSON C, et al. An Intravascular tantalum oxide-based CT contrast agent:preclinical evaluation emulating overweight and obese patient size[J]. Radiology,2018,289(1):103-110.
[16] SI-MOHAMED S, CORMODE D P, BAR-NESS D, et al. Evaluation of spectral photon counting computed tomography K-edge imaging for determination of gold nanoparticle biodistribution in vivo[J]. Nanoscale,2017,9(46):18246-18257.
[17] DUNNING C, O'CONNELL J, ROBINSON S M, et al. Photon-counting computed tomography of lanthanide contrast agents with a high-flux 330-μm-pitch cadmium zinc telluride detector in a table-top system[J]. J Med Imaging (Bellingham),2020,7(3):033502.
[18] LIN H, XU X, DENG R, et al. Photon-counting detector CT for liver fat quantification:validation across protocols in metabolic dysfunction-associated steatotic liver disease[J]. Radiology,2024,312(3):e240038.
[19] SCHWARTZ F R, ASHTON J, WILDMAN-TOBRINER B, et al. Liver fat quantification in photon counting CT in head to head comparison with clinical MRI - first experie-nce[J]. Eur J Radiol,2023,161:110734.
[20] CURTIS W A, FRAUM T J, AN H, et al. Quantitative MRI of diffuse liver disease:current applications and future directions[J]. Radiology,2019,290(1):23-30.
[21] HAO W, XU Z, LIN H, et al. Using dual-source photon-counting detector CT to simultaneously quantify fat and iron content: a phantom study[J]. Acad Radiol,2024,31(10),4119-4128.
[22] YANG Y, QIN L, LIN H, et al. Consistency of monoenergetic attenuation measurements for a clinical dual-source photon-counting detector CT system across scanning paradigms:a phantom study[J]. AJR Am J Roentgenol,2024,222(5):e2330631.
[23] SARTORETTI T, MERGEN V, HIGASHIGAITO K, et al. Virtual noncontrast imaging of the liver using photon-counting detector computed tomography:a systematic phantom and patient study[J]. Invest Radiol,2022,57(7):488-493.
[24] SARTORETTI T, MERGEN V, JUNGBLUT L, et al. Liver Iodine quantification with photon-counting detector CT:accuracy in an abdominal phantom and feasibility in patients[J]. Acad Radiol,2023,30(3):461-469.
[25] SAWALL S, KLEIN L, AMATO C, et al. Iodine contrast-to-noise ratio improvement at unit dose and contrast media volume reduction in whole-body photon-counting CT[J]. Eur J Radiol,2020,126:108909.
[26] HIGASHIGAITO K, EULER A, EBERHARD M, et al. Contrast-enhanced abdominal CT with clinical photon-counting detector CT:assessment of image quality and comparison with energy-integrating detector CT[J]. Acad Radiol,2022,29(5):689-697.
[27] SARTORETTI T, LANDSMANN A, NAKHOSTIN D, et al. Quantum iterative reconstruction for abdominal photon-counting detector CT improves image quality[J]. Radiology,2022,303(2):339-348.
[28] BETTE S, DECKER J A, BRAUN F M, et al. Optimal conspicuity of liver metastases in virtual monochromatic imaging reconstructions on a novel photon-counting detector CT-effect of keV settings and BMI[J]. Diagnostics (Basel),2022,12(5):1231.
[29] IPPOLITO D, PECORELLI A, QUERQUES G, et al. Dynamic computed tomography perfusion imaging:complementary diagnostic tool in hepatocellular carcinoma assessment from diagnosis to treatment follow-up[J]. Acad Radiol,2019,26(12):1675-1685.
[30] KIM K W, LEE J M, KLOTZ E, et al. Quantitative CT color mapping of the arterial enhancement fraction of the liver to detect hepatocellular carcinoma[J]. Radiology,2009,250(2):425-434.
[31] FISCHER M A, KARTALIS N, GRIGORIADIS A, et al. Perfusion computed tomography for detection of hepatocellular carcinoma in patients with liver cirrhosis[J]. Eur Radiol,2015,25(11):3123-3132.
[32] TSUSHIMA Y, BLOMLEY M J, YOKOYAMA H, et al. Does the presence of distant and local malignancy alter parenchymal perfusion in apparently disease-free areas of the liver[J]. Dig Dis Sci,2001,46(10):2113-2119.
[33] CUENOD C, LECONTE I, SIAUVE N, et al. Early changes in liver perfusion caused by occult metastases in rats: detection with quantitative CT[J]. Radiology,2001,218(2):556-561.
[34] ABDULLAH S S, PIALAT J B, WIART M, et al. Characterization of hepatocellular carcinoma and colorectal liver metastasis by means of perfusion MRI[J]. J Magn Reson Imaging,2008,28(2):390-395.
[35] LEWIN M, LAURENT-BELLUE A, DESTERKE C, et al. Evaluation of perfusion CT and dual-energy CT for predicting microvascular invasion of hepatocellular carcinoma[J]. Abdom Radiol (NY),2022,47(6):2115-2127.
[36] KIM S H, KAMAYA A, WILLMANN J K. CT perfusion of the liver:principles and applications in oncology[J]. Radio-logy,2014,272(2):322-344.
[37] KIM D H, KIM S H, IM S A, et al. Intermodality comparison between 3D perfusion CT and 18F-FDG PET/CT imaging for predicting early tumor response in patients with liver metastasis after chemotherapy: preliminary results of a prospective study[J]. Eur J Radiol,2012,81(11):3542-3550.
[38] REN Y, FLEISCHMANN D, FOYGEL K, et al. Antiangiogenic and radiation therapy:early effects on in vivo computed tomography perfusion parameters in human colon cancer xenografts in mice[J]. Invest Radiol,2012,47(1):25-32.
[39] YANG L, ZHANG X M, TAN B X, et al. Computed tomographic perfusion imaging for the therapeutic response of chemoembolization for hepatocellular carcinoma[J]. J Comput Assist Tomogr,2012,36(2):226-230.
[40] PERISINAKIS K, TZEDAKIS A, POULI S, et al. Comparison of patient dose from routine multi-phase and dynamic liver perfusion CT studies taking into account the effect of iodinated contrast administration[J]. Eur J Radiol,2019,110:39-44.
Outlines

/