新型腹膜透析导管固定腰带的临床应用效果观察

卫诺(), 黄晓敏, 张春燕, 陈伟红()   

  1. 上海交通大学医学院附属瑞金医院肾脏内科,上海 200025
  • 收稿日期:2025-01-13 修回日期:2025-04-14 出版日期:2026-06-25 发布日期:2026-08-19
  • 通讯作者: 陈伟红 E-mail:cwh20319@rjh.com.cn
  • 作者简介:作者贡献/Authors’ Contributions卫诺负责构思与设计,研究的实施与可行性分析,资料收集和整理,统计学处理,论文撰写和修订;黄晓敏和张春燕负责资料收集和整理;陈伟红负责专利转化、文章修订,质量控制及审校。
  • 基金资助:
    上海交通大学医学院附属瑞金医院护理专项基金(RJHK2023-036)

Clinical application of a novel belt for securing peritoneal dialysis catheters

WEI Nuo(), HUANG Xiaomin, ZHANG Chunyan, CHEN Weihong()   

  1. Department of Nephrology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China
  • Received:2025-01-13 Revised:2025-04-14 Online:2026-06-25 Published:2026-08-19

摘要:

目的:探讨新型腹膜透析(peritoneal dialysis, PD)导管固定腰带的临床应用效果。方法:选取2023年7月至2024年4月在上海某三级甲等医院长期随访的PD患者100例,采用随机数字表法分为观察组和对照组,各50例。观察组采用新型PD腰带固定导管,以无菌开口纱布覆盖出口处。对照组采用传统PD腰带固定导管,以无菌敷贴(6 cm × 7 cm)覆盖出口处。2组患者分别于干预后第1、7、30、90天各进行1次出口评分系统评分和《PD导管固定腰带临床应用调查表》评价。结果:观察组在出口处周围皮肤医用黏胶相关性皮肤损伤(medical adhesive-related skin injury, MARSI)发生率、导管弯折和导管牵拉发生率、PD换液操作便捷性、耗材费用等方面均显著优于对照组(P<0.05)。结论:新型PD腰带的使用能降低出口处周围皮肤MARSI发生率,有效保障PD导管安全性,并降低PD导管出口处日常维护的经济成本。

关键词: 腹膜透析, 出口处评分, 医用黏胶相关性皮肤损伤

Abstract:

Objective To investigate the clinical application effect of a new type of peritoneal dialysis (PD) catheter holder belt. Methods From July 2023 to April 2024, 100 long-term follow-up PD patients in a tertiary hospital in Shanghai were randomly divided into an observation group of 50 patients and a control group of 50 patients. In the observation group, the novel PD belt was used to secure the catheter, and the exit site was covered with a sterile gauze with an opening. In the control group, a traditional PD belt was used to secure the catheter, and the exit site was covered with a sterile dressing (6 cm×7 cm). The 2 groups were evaluated at 1, 7, 30, and 90 days after intervention using the exit-site scoring system and the "Clinical Application Questionnaire of the PD Catheter Holder Belt". Results The observation group was significantly superior to the control group in terms of the incidence of medical adhesive-related skin injury (MARSI) around the exit site, the incidence of catheter bending and catheter traction, the convenience of PD fluid exchange, and the cost of consumables (all P<0.05). Conclusions The use of the novel PD belt can reduce the incidence of MARSI around the exit site, effectively ensure the safety of the PD catheter, and reduce the economic cost of PD catheter exit-site care.

Key words: peritoneal dialysis, exit-site scoring, medical adhesive-related skin injury

中图分类号: