Objective: To investigate the value of Multivane XD technique in liver T2-weighted imaging (T2WI). Methods: Fifty-six patients(29 men, 27 women; age ranged 25-84 years, average 54 years) underwent liver MR imaging including conventional T2WI and Multivane XD T2WI were analyzed. Sixteen patients had focal hepatic lesions (FHL). Qualitative analysis was performed by two abdominal radiologists. Overall image quality was scored 5-scales ranged from 1 to 5. Signal intensity of right lobe, left lobe and FHL, and background SD were measured. SNRright lobe, SNRleft lobe, CNRright lobe, CNRleft lobe and contrast between FHL and liver parenchyma were calculated and compared between Multivane XD T2WI and conventional T2WI. Results: Overall image quality score of Multivane XD T2WI was significantly higher than that of conventional T2WI [(4.70±0.50) vs (2.86±0.80), P=0.001]. SNRright lobe and SNRleft lobe were significantly higher than those of conventional T2WI [(189.84±112.39) vs(3.52±70.08), P<0.001; (218.82±136.24) vs (28.70±96.97), P<0.001]. There was no significant difference in CNRright lobe, CNRleft lobe and contrast [(4.30±51.86) vs (3.52±70.08), P=0.447; (24.68±82.61) vs (28.67±96.95), P=0.742; (2.94±1.43) vs (2.92±1.16), P=0.958] between Multivane XD T2WI and conventional T2WI. Conclusions: Multivane XD technique can reduce motion artifacts and improve the imaging quality of T2WI.
WANG Tao, FU Meng, XIAO Ruijie, DONG Haipeng, LI Ruokun, YAN Fuhua
. Application of Multivane XD technique in liver T2-weighted imaging[J]. Journal of Diagnostics Concepts & Practice, 2016
, 15(05)
: 521
-524
.
DOI: 10.16150/j.1671-2870.2016.05.018
[1] Schima W, Saini S, Echeverri JA, et al.Focal liver lesions: characterization with conventional spin-echo versus fast spin-echo T2-weighted MR imaging[J]. Radiology,1997,202(2):389-393.
[2] Siegelman ES, Chauhan A.MR characterization of focal liver lesions: pearls and pitfalls[J]. Magn Reson Imaging Clin N Am,2014,22(3):295-313.
[3] Hirokawa Y, Isoda H, Maetani YS, et al.Hepatic lesions: improved image quality and detection with the periodically rotated overlapping parallel lines with enhanced reconstruction technique--evaluation of SPIO-enhanced T2-weighted MR images[J]. Radiology,2009,251(2):388-397.
[4] Haneder S, Dinter D, Gutfleisch A, et al.Image quality of T2w-TSE of the abdomen and pelvis with Cartesian or BLADE-type k-space sampling: a retrospective interindividual comparison study[J]. Eur J Radiol,2011,79(2):177-182.
[5] Rosenkrantz AB, Mannelli L, Mossa D, et al.Breath-hold T2-weighted MRI of the liver at 3T using the BLADE technique: impact upon image quality and lesion detection[J]. Clin Radiol,2011,66(5):426-433.
[6] Kang KA, Kim YK, Kim E, et al.T2-weighted liver MRI using the multiVane technique at 3T: Comparison with conventional T2-weighted MRI[J]. Korean J Radiol,2015, 16(5):1038-1046.
[7] 戈明媚, 王秋良, 刘志钦, 等. MR螺旋桨扫描技术在消除伪影方面的临床应用[J]. 中华放射学杂志,2006,40(2)208-212.
[8] 朱乃懿, 周惠娟, 郭斯敏, 等. 肝纤维化磁共振扩散相关成像与病理学结果关系的对照研究[J]. 诊断学理论与实践,2015,14(1):41-45.
[9] van Heeswijk RB, Bonanno G, Coppo S, et al. Motion compensation strategies in magnetic resonance imaging[J]. Crit Rev Biomed Eng,2012,40(2):99-119.
[10] Hirokawa Y, Isoda H, Maetani YS, et al.MRI artifact reduction and quality improvement in the upper abdomen with PROPELLER and prospective acquisition correction (PACE) technique[J]. Am J Roentgenol,2008,191(4):1154-1158.
[11] Chang Y, Pipe JG, Karis JP, et al.The effects of SENSE on PROPELLER imaging[J]. Magn Reson Med,2015,74(6):1598-1608.