综述

保乳手术术中切缘评估技术的现状与进展

  • 金小丁 综述 ,
  • 邹强 ,
  • 金贻婷 审校
展开
  • 复旦大学附属华山医院普外科 甲乳外科中心,上海 200040
金贻婷,E-mail: clara_raky@aliyun.com

收稿日期: 2024-09-09

  网络出版日期: 2025-07-07

Intraoperative margin assessment techniques in breast-conserving surgery: current status and advances

  • JIN Xiaoding ,
  • ZOU Qiang ,
  • JIN Yiting
Expand
  • Department of Thyroid and Breast Surgery, General Surgery, Huashan Hospital, Fudan University, Shanghai 200040, China

Received date: 2024-09-09

  Online published: 2025-07-07

摘要

对于保乳手术而言,术中及时而准确的切缘评估是确保手术成功与降低局部复发率的关键。本文首先回顾了目前保乳手术中所使用的切缘评估方法,包括快速病理学检查和标本影像学检查技术。根据技术路径分类,系统地介绍了近年来发展迅速的新兴技术,涵盖高级显微镜、传统影像技术的发展、新兴成像技术以及关注组织生化特性和电特性差异的技术等方向。对上述技术进行总结与横向比较,并结合外科临床需求提出若干评估维度,以期为术中切缘评估技术的优化选择与临床转化提供参考。尽管新技术蓬勃发展,仍需进一步的临床研究和技术改进,不断优化和创新,为病人提供更好的选择。

本文引用格式

金小丁 综述 , 邹强 , 金贻婷 审校 . 保乳手术术中切缘评估技术的现状与进展[J]. 外科理论与实践, 2025 , 30(2) : 176 -182 . DOI: 10.16139/j.1007-9610.2025.02.14

Abstract

In breast-conserving surgery, timely and accurate intraoperative margin assessment is crucial for ensuring surgical success and reducing local recurrence rates. This review first outlined the current methods for intraoperative margin evaluation, including rapid pathological examination and specimen imaging techniques. According to the technical classification, this review systematically introduced emerging technologies that have advanced significantly in recent years, encompassing advanced microscopy, advancements in conventional imaging technologies, novel imaging technologies, and techniques based on biochemical and electrical property contrasts of tissues. Finally, the review summarized and compared these technologies horizontally, and proposed several assessment dimensions aligned with surgical clinical needs, aiming to support the optimization and clinical translation of intraoperative margin assessment techniques. Despite the vigorous development of new technologies, further clinical research and technical refinement remain necessary to achieve continuous improvement and innovation, ultimately providing better options for the patients.

参考文献

[1] MORROW M, HARRIS J R, SCHNITT S J. Surgical margins in lumpectomy for breast cancer - bigger is not better[J]. N Engl J Med, 2012, 367(1):79-82.
[2] ST JOHN E R, AL-KHUDAIRI R, ASHRAFIAN H, et al. Diagnostic accuracy of intraoperative techniques for margin assessment in breast cancer surgery: a meta-analysis[J]. Ann Surg, 2017, 265(2):300-310.
[3] RIEDL O, FITZAL F, MADER N, et al. Intraoperative frozen section analysis for breast-conserving therapy in 1016 patients with breast cancer[J]. Eur J Surg Oncol, 2009, 35(3):264-270.
[4] D'HALLUIN F, TAS P, ROUQUETTE S, et al. Intra-operative touch preparation cytology following lumpectomy for breast cancer: a series of 400 procedures[J]. Breast, 2009, 18(4):248-253.
[5] RAMOS M, DíAZ J C, RAMOS T, et al. Ultrasound-guided excision combined with intraoperative assessment of gross macroscopic margins decreases the rate of reoperations for non-palpable invasive breast cancer[J]. Breast, 2013, 22(4):520-524.
[6] TAO Y K, SHEN D, SHEIKINE Y, et al. Assessment of breast pathologies using nonlinear microscopy[J]. Proc Natl Acad Sci USA, 2014, 111(43):15304-15309.
[7] CAHILL L C, GIACOMELLI M G, YOSHITAKE T, et al. Rapid virtual hematoxylin and eosin histology of breast tissue specimens using a compact fluorescence nonlinear microscope[J]. Lab Invest, 2018, 98(1):150-160.
[8] TOGAWA R, HEDERER J, RAGAZZI M, et al. Imaging of lumpectomy surface with large field-of-view confocal laser scanning microscopy 'Histolog? scanner' for breast margin assessment in comparison with conventional specimen radiography[J]. Breast, 2023,68:194-200.
[9] CHANG T P, LEFF D R, SHOUSHA S, et al. Imaging breast cancer morphology using probe-based confocal laser endomicroscopy: towards a real-time intraoperative imaging tool for cavity scanning[J]. Breast Cancer Res Treat, 2015, 153(2):299-310.
[10] ZHANG Y, XIE M, XUE R, et al. A novel cell morpho-logy analyzer application in head and neck cancer[J]. Int J Gen Med, 2021,14:9307-9314.
[11] CHEN J J, YU B H, SHEN T J, et al. A prospective comparison of a modified miniaturised hand-held epifluorescence microscope and touch imprint cytology for evaluation of axillary sentinel lymph nodes intraoperatively in breast cancer patients[J]. Cytopathology, 2024, 35(1):136-144.
[12] YOSHITAKE T, GIACOMELLI M G, QUINTANA L M, et al. Rapid histopathological imaging of skin and breast cancer surgical specimens using immersion microscopy with ultraviolet surface excitation[J]. Sci Rep, 2018, 8(1):4476.
[13] YANG Y, LIU Z, HUANG J, et al. Histological diagnosis of unprocessed breast core-needle biopsy via stimulated Raman scattering microscopy and multi-instance learning[J]. Theranostics, 2023, 13(4):1342-1354.
[14] ORRINGER D A, PANDIAN B, NIKNAFS Y S, et al. Rapid intraoperative histology of unprocessed surgical specimens via fibre-laser-based stimulated Raman scattering microscopy[J]. Nat Biomed Eng,2017, 1:0027
[15] FU H L, MUELLER J L, JAVID M P, et al. Optimization of a widefield structured illumination microscope for non-destructive assessment and quantification of nuclear features in tumor margins of a primary mouse model of sarcoma[J]. PLoS One, 2013, 8(7):e68868.
[16] MCCLATCHY D M, RIZZO E J, MEGANCK J, et al. Calibration and analysis of a multimodal micro-CT and structured light imaging system for the evaluation of excised breast tissue[J]. Phys Med Biol, 2017, 62(23):8983-9000.
[17] TANG R, COOPEY S B, BUCKLEY J M, et al. A pilot study evaluating shaved cavity margins with micro-computed tomography: a novel method for predicting lumpectomy margin status intraoperatively[J]. Breast J, 2013, 19(5):485-489.
[18] THILL M, SZWARCFITER I, KELLING K, et al. Magnetic resonance imaging system for intraoperative margin assessment for DCIS and invasive breast cancer using the ClearSight? system in breast-conserving surgery-results from a postmarketing study[J]. J Surg Oncol, 2022, 125(3):361-368.
[19] WATANABE G, ITOH M, DUAN X, et al. 18F-fluorodeoxyglucose specimen-positron emission mammography delineates tumour extension in breast-conserving surgery: preliminary results[J]. Eur Radiol, 2018, 28(5):1929-1937.
[20] GROOTENDORST M R, CARIATI M, PINDER S E, et al. Intraoperative assessment of tumor resection margins in breast-conserving surgery using 18F-FDG cerenkov luminescence imaging: a first-in-human feasibility study[J]. J Nucl Med, 2017, 58(6):891-898.
[21] NGUYEN F T, ZYSK A M, CHANEY E J, et al. Intra-operative evaluation of breast tumor margins with optical coherence tomography[J]. Cancer Res, 2009, 69(22):8790-8796.
[22] ALLEN W M, FOO K Y, ZILKENS R, et al. Clinical feasibility of optical coherence micro-elastography for imaging tumor margins in breast-conserving surgery[J]. Biomed Opt Express, 2018, 9(12):6331-6349.
[23] SOUTH F A, CHANEY E J, MARJANOVIC M, et al. Differentiation of ex vivo human breast tissue using polarization-sensitive optical coherence tomography[J]. Biomed Opt Express, 2014, 5(10):3417-3426.
[24] ERICKSON-BHATT S J, NOLAN R M, SHEMONSKI N D, et al. Real-time imaging of the resection bed using a handheld probe to reduce incidence of microscopic positive margins in cancer surgery[J]. Cancer Res, 2015, 75(18):3706-3712.
[25] KHO E, DE BOER L L, VAN DE VIJVER K K, et al. Hyperspectral imaging for resection margin assessment during cancer surgery[J]. Clin Cancer Res, 2019, 25(12):3572-3580.
[26] FITZGERALD A J, WALLACE V P, JIMENEZ-LINAN M, et al. Terahertz pulsed imaging of human breast tumors[J]. Radiology, 2006, 239(2):533-540.
[27] GROOTENDORST M R, FITZGERALD A J, BROUWER DE KONING S G, et al. Use of a handheld terahertz pulsed imaging device to differentiate benign and malignant breast tissue[J]. Biomed Opt Express, 2017, 8(6):2932-2945.
[28] SADEGHI A, NAGHAVI S M H, MOZAFARI M, et al. Nanoscale biomaterials for terahertz imaging: a non-invasive approach for early cancer detection[J]. Transl Oncol,2023, 27:101565
[29] NYAYAPATHI N, XIA J. Photoacoustic imaging of breast cancer: a mini review of system design and image features[J]. J Biomed Opt, 2019, 24(12):1-13.
[30] LI R, LAN L, XIA Y, et al. High-speed intraoperative assessment of breast tumor margins by multimodal ultrasound and photoacoustic tomography[J]. Med Devices Sens, 2018, 1(3):e10018.
[31] EGLOFF-JURAS C, BEZDETNAYA L, DOLIVET G, et al. NIR fluorescence-guided tumor surgery: new strategies for the use of indocyanine green[J]. Int J Nanomedicine, 2019,14:7823-7838.
[32] TUMMERS Q R, VERBEEK F P, SCHAAFSMA B E, et al. Real-time intraoperative detection of breast cancer using near-infrared fluorescence imaging and methylene blue[J]. Eur J Surg Oncol, 2014, 40(7):850-858.
[33] LAMBERTS L E, KOCH M, DE JONG J S, et al. Tumor-specific uptake of fluorescent bevacizumab-IRDye800CW microdosing in patients with primary breast cancer: a phase -Ⅰ feasibility study[J]. Clin Cancer Res, 2017, 23(11):2730-2741.
[34] DINTZIS S M, HANSEN S, HARRINGTON K M, et al. Real-time visualization of breast carcinoma in pathology specimens from patients receiving fluorescent tumor-marking agent tozuleristide[J]. Arch Pathol Lab Med, 2019, 143(9):1076-1083.
[35] SMITH B L, GADD M A, LANAHAN C R, et al. Real-time, intraoperative detection of residual breast cancer in lumpectomy cavity walls using a novel cathepsin-activated fluorescent imaging system[J]. Breast Cancer Res Treat, 2018, 171(2):413-420.
[36] MIAMPAMBA M, LIU J, HAROOTUNIAN A, et al. Sensitive in vivo visualization of breast cancer using ratiometric protease-activatable fluorescent imaging agent, AVB-620[J]. Theranostics, 2017, 7(13):3369-3386.
[37] MONDAL S B, GAO S, ZHU N, et al. Binocular goggle augmented imaging and navigation system provides real-time fluorescence image guidance for tumor resection and sentinel lymph node mapping[J]. Sci Rep, 2015, 5:12117.
[38] KELLER M D, MAJUMDER S K, KELLEY M C, et al. Autofluorescence and diffuse reflectance spectroscopy and spectral imaging for breast surgical margin analysis[J]. Lasers Surg Med, 2010, 42(1):15-23.
[39] PHIPPS J E, GORPAS D, UNGER J, et al. Automated detection of breast cancer in resected specimens with fluorescence lifetime imaging[J]. Phys Med Biol, 2017, 63(1):015003.
[40] Zú?IGA W C, JONES V, ANDERSON S M, et al. Raman spectroscopy for rapid evaluation of surgical margins during breast cancer lumpectomy[J]. Sci Rep, 2019, 9(1):14639.
[41] YIN H, JIN Z, DUAN W, et al. Emergence of responsive surface-enhanced raman scattering probes for imaging tumor-associated metabolites[J]. Adv Healthc Mater, 2022, 11(12):e2200030.
[42] WANG Y, KANG S, KHAN A, et al. Quantitative molecular phenotyping with topically applied SERS nanoparticles for intraoperative guidance of breast cancer lumpectomy[J]. Sci Rep,2016, 6:21242
[43] WANG Y W, REDER N P, KANG S, et al. Raman-encoded molecular imaging with topically applied SERS nanoparticles for intraoperative guidance of lumpectomy[J]. Cancer Res, 2017, 77(16):4506-4516.
[44] JIN Z, YUE Q, DUAN W, et al. Intelligent SERS navigation system guiding brain tumor surgery by intraoperatively delineating the metabolic acidosis[J]. Adv Sci (Weinh), 2022, 9(7):e2104935.
[45] THOMAS G, NGUYEN T Q, PENCE I J, et al. Evaluating feasibility of an automated 3-dimensional scanner using Raman spectroscopy for intraoperative breast margin assessment[J]. Sci Rep, 2017, 7(1):13548.
[46] BROWN J Q, BYDLON T M, KENNEDY S A, et al. Optical spectral surveillance of breast tissue landscapes for detection of residual disease in breast tumor margins[J]. PLoS One, 2013, 8(7):e69906.
[47] DE BOER L L, MOLENKAMP B G, BYDLON T M, et al. Fat/water ratios measured with diffuse reflectance spectroscopy to detect breast tumor boundaries[J]. Breast Cancer Res Treat, 2015, 152(3):509-518.
[48] BALOG J, SASI-SZABó L, KINROSS J, et al. Intraoperative tissue identification using rapid evaporative ionization mass spectrometry[J]. Sci Transl Med, 2013, 5(194):194ra93.
[49] CALLIGARIS D, CARAGACIANU D, LIU X, et al. Application of desorption electrospray ionization mass spectrometry imaging in breast cancer margin analysis[J]. Proc Natl Acad Sci USA, 2014, 111(42):15184-15189.
[50] SCHARTNER E P, HENDERSON M R, PURDEY M, et al. Cancer detection in human tissue samples using a fiber-tip pH probe[J]. Cancer Res, 2016, 76(23):6795-6801.
[51] THILL M, DITTMER C, BAUMANN K, et al. MarginProbe?-final results of the German post-market study in breast conserving surgery of ductal carcinoma in situ[J]. Breast, 2014, 23(1):94-96.
[52] DIXON J M, RENSHAW L, YOUNG O, et al. Intra-operative assessment of excised breast tumour margins using ClearEdge imaging device[J]. Eur J Surg Oncol, 2016, 42(12):1834-1840.
[53] VARTHOLOMATOS G, HARISSIS H, ANDREOU M, et al. Rapid assessment of resection margins during breast conserving surgery using intraoperative flow cytometry[J]. Clin Breast Cancer, 2021, 21(5):e602-e610.
[54] DICORPO D, TIWARI A, TANG R, et al. The role of Micro-CT in imaging breast cancer specimens[J]. Breast Cancer Res Treat, 2020, 180(2):343-357.
文章导航

/