Objective To study the effect of using head thermoplastic mask and breast bracket combined with body marker to decrease setup errors in intensity-modulated radiotherapy (IMRT) of chest wall and clavicular region. Methods Ten breast cancer patients receiving IMRT on chest wall and sup/infraclavicular regional lymph nodes after breast surgery were enrolled. Each patient with breast bracket was immobilized into 3 positions: using breast bracket only (group A), using body marker with breast bracket (group B) and using body marker and head thermoplastic mask with breast bracket (group C). Setup errors of irradiation field center, spinous process of clavicular region and clavicle were examined using X-ray simulator once a week for 5 week with each position and compared. All ten patients were treated IMRT with position in group C. Results A total of 141 set of data in all 3 groups (47 set of data each group) were gotten. The setup errors of irradiation field center in 3 directions of left-right, superior-inferior and anterior-posterior in group C were significantly less than those in group A and B (P<0.05). Setup errors of spinous process of clavicular region in left-right direction increased with the distance from inferior margin to above of clavicular head. There were 12.8%, 6.4% and 2.1% of setup errors more than 5 mm in left-right direction at 6 cm above clavicular head in group A, B and C, respectively. Setup errors of patients in group C were significantly less than those in group A and B (P<0.05) except for those of superior margin of clavicular head and 1 cm, 2 cm above clavicular head. Setup errors of clavicle in superior-inferior direction in group C were significantly less than those in group A and B (P<0.001). Conclusions Head thermoplastic mask and breast bracket combined with body markers could reduce setup errors of irradiation field center, spinous process of clavicular region and clavicle, which improved setup accuracy of IMRT for breast cancer patients.
JIANG Qing, ZHU Ming, XU Cheng, WANG Shubei, CAO Lu, CAI Rong, CHEN Jiayi, CAI Gang
. Use head thermoplastic mask and breast bracket with body markers for breast cancer patient improves setup accuracy of intensity-modulated radiotherapy[J]. Journal of Surgery Concepts & Practice, 2019
, 24(05)
: 446
-451
.
DOI: 10.16139/j.1007-9610.2019.05.015
[1] EBCTCG (Early Breast Cancer Trialists′ Collaborative Group), McGale P, Taylor C, et al. Effect of radiotherapy after mastectomy and axillary surgery on 10-year recurrence and 20-year breast cancer mortality: meta-analysis of individual patient data for 8135 women in 22 randomised trials[J]. Lancet,2014,383(9935):2127-2135.
[2] Gradishar WJ, Anderson BO, Balassanian R, et al.NCCN Guidelines Insights: breast cancer, version 1.2017[J]. J Natl Compr Canc Netw,2017,15(4):433-451.
[3] Offersen BV, Boersma LJ, Kirkove C, et al.ESTRO consensus guideline on target volume delineation for elective radiation therapy of early stage breast cancer[J]. Radiother Oncol,2015,114(1):3-10.
[4] Ma J, Li J, Xie J, et al.Post mastectomy linac IMRT irradiation of chest wall and regional nodes: dosimetry data and acute toxicities[J]. Radiat Oncol,2013,8:81.
[5] Poortmans PM, Collette S, Kirkove C, et al.Internal mammary and medial supraclavicular irradiation in breast cancer[J]. N Engl J Med,2015,373(4):317-327.
[6] Whelan TJ, Olivotto IA, Parulekar WR, et al.Regional nodal irradiation in early-stage breast cancer[J]. N Engl J Med,2015,373(4):307-316.
[7] 陈剑, 马金利, 张盛箭, 等. 局部晚期和复发性乳腺癌病人·区域淋巴结转移分布特点及靶区勾画意义[J]. 中华放射肿瘤学杂志,2011,20(2):123-127.
[8] 吴传锋, 吴锦昌, 顾科, 等. 水固化头枕对提高乳腺托架固定下乳腺癌放疗锁骨上野摆位准确性的研究[J]. 中华放射医学与防护杂志,2017,37(9):686-689.
[9] 谢涛, 许青, 彭佳元, 等. 乳腺癌胸壁野结合锁骨上野放疗时头部固定的重要性研究[J]. 中华放射肿瘤学杂志,2018,27(5):500-503.
[10] 胡乃军, 蔡钢, 许青, 等. 早期乳腺癌保乳术后不同固定装置下全乳照射的摆位误差分析[J]. 中国癌症杂志,2015,25(11):911-916.
[11] Batumalai V, Holloway L, Delaney GP.A review of setup error in supine breast radiotherapy using cone-beam computed tomography[J]. Med Dosim,2016,41(3):225-229.
[12] 陈林, 胡洪涛, 云惟康, 等. 乳腺癌放疗体位固定技术的改进[J]. 中华放射肿瘤学杂志,2007,16(6):490-491.
[13] 李俊禹, 李廷廷, 陈吉祥, 等. 体膜联合乳腺托架固定在乳腺癌保乳术后放疗中的应用[J]. 实用癌症杂志,2017,32(4):556-558.
[14] 付秀根, 熊华, 郑祖安, 等. 颈胸一体热塑膜固定下乳腺癌放疗摆位误差分析[J]. 肿瘤研究与临床,2018,30(6):374-378.
[15] 吴传锋, 吴锦昌, 顾科, 等. 利用CBCT研究乳腺托架固定下乳腺癌放疗下颈摆位误差及相应CTV外放边界[J]. 中华放射医学与防护杂志,2016,36(10):753-756.
[16] Korreman S, Rasch C, McNair H, et al. The European Society of Therapeutic Radiology and Oncology-European Institute of Radiotherapy (ESTRO-EIR) report on 3D CT-based in-room image guidance systems: a practical and technical review and guide[J]. Radiother Oncol,2010,94(2):129-144.