Discussion on the Solution of Insulation Failure of Underwater Motor on Offshore Platform

  • DENG Guanhua ,
  • ZHANG Guodong ,
  • YANG Qifu ,
  • YANG Sen ,
  • CEN Jianfeng
Expand
  • Zhanjiang Oil Production Services Wenchang Co., CNOOC Energy Technology & Services Limited, Zhanjiang 524057, Guangdong China

Online published: 2024-07-05

Abstract

Aiming at the problems of high insulation failure rate and unstable quality of domestic electric seawater lifting pump motor. By combining the actual cases and the simulation analysis of temperature field, it is concluded that the main reasons for the insulation failure of submerged water motor include the defect of winding wire selection, insufficient internal heat dissipation, poor sealing performance and lack of temperature monitoring. At the same time, according to the reason of appeal, the feasible improvement method is put forward in order to improve the product quality of electric submersible water pump.

Cite this article

DENG Guanhua , ZHANG Guodong , YANG Qifu , YANG Sen , CEN Jianfeng . Discussion on the Solution of Insulation Failure of Underwater Motor on Offshore Platform[J]. Ocean Engineering Equipment and Technology, 2024 , 11(2) : 15 -19 . DOI: 10.12087/oeet.2095-7297.2024.02.04