Feasibility of dual-energy CT in evaluation of marrow edema of gouty arthritis
Received date: 2019-03-20
Online published: 2019-06-25
Objective: To investigate the feasibility of dual-energy CT in the evaluation of marrow edema of gouty arthritis. Methods: One hundred and sixty-one patients who had undergone plain dual-energy CT and diagnosed as gout between January 2017 and June 2018 were retrospectively analyzed. All examinations were performed on dual-source CT (Somaton Definition Flash, Siemens, Germany) with tube voltage of Sn140 kVp and 80 kVp. Then the images were transferred to Syngo. via (Siemens, Germany) postprocessing workstation for further analysis with 'marrow edema' module to diagnose marrow edema and acquire CT values on (double energy-virtual non-calcium, DE-VNC) images. MRI images of corresponding sites were also analyzed by the sequence of T1WI (T1 weighted imaging), T2WI (T2 weighted imaging) and STIR (short T1 inversion recovery). Results: After being analyzed by Syngo.via postprocessing workstation, it had been demonstrated that CT values between sites with marrow edema, sites adjacent to marrow edema and sites distant to marrow edema had significant differences (P<0.05). Based on the golden standard of MRI images, the diagnostic sensitivity, specificity, positive predictive value and negative predictive value of dual-energy CT was 82.2%, 90.7%, 86% and 88.1%, respectively. Twelve missed cases was due to widespread bone destruction. Conclusions: Not only could dual-energy CT detect gouts, it also has good diagnostic accuracy in the evaluation of marrow edema of gouty arthritis. Cases with widespread bone destruction may be missed.
Key words: Dual-energy CT; Gout; Marrow edema
ZHU Siqi, WU Mengxiong, QIN Le, DONG Haipeng . Feasibility of dual-energy CT in evaluation of marrow edema of gouty arthritis[J]. Journal of Diagnostics Concepts & Practice, 2019 , 18(03) : 340 -343 . DOI: 10.16150/j.1671-2870.2019.03.018
[1] | Dalbeth N, Doyle A, McQueen FM. Imaging in gout: insights into the pathological features of disease[J]. Curr Opin Rheumatol, 2012, 24(2):132-138. |
[2] | Glazebrook KN, Guimarães LS, Murthy NS, et al. Identification of intraarticular and periarticular uric acid crystals with dual-energy CT: initial evaluation[J]. Radiology, 2011, 261(2):516-524. |
[3] | 秦维昌. 双源双能量CT成像的技术进展[J]. 中国医疗设备, 2012, 27(3):61. |
[4] | 王刚. 双源CT双能量成像对痛风诊断价值的初步研究[J]. 世界最新医学信息文摘, 2015, 15(63):99. |
[5] | 郭润竹, 王雄, 邹吉利, 等. 痛风治疗药物的研究进展[J]. 临床医学, 2017, 23(16):3265-3269. |
[6] | 窦小峰, 张波, 田为中, 等. 双源CT双能量成像在痛风诊断中价值的初步研究[J]. 临床放射学杂志, 2013, 32(4):555-558. |
[7] | 黄锦炽, 刘东旭, 赵欣, 等. 双源CT双能量成像对痛风结晶诊断的临床应用价值[J]. 现代诊断与治疗, 2015, 26(21):4991-4992. |
[8] | Coursey CA, Nelson RC, Boll DT, et al. Dual-energy multidetector CT: how does it work, what can it tell us, and when can we use it in abdominopelvic imaging?[J]. Radiographics, 2010, 30(4):1037-1055. |
[9] | 张园园, 赵建农, 陈君辉, 等. 膝关节痛风性关节炎MRI表现分析[J]. 磁共振成像, 2016, 7(5):376-378. |
[10] | 罗是是, 王振平, 陈峰, 等. 痛风性膝关节炎的MRI诊断[J]. 实用医学杂志, 2018, 34(4):645-648. |
[11] | 于建秀, 宋修恩. 痛风性关节炎的影像学诊断进展[J]. 医学影像学杂志, 2017, 27(5):926-928. |
[12] | 莫守崎, 李依蓝, 蔡瑜彬, 等. 双能CT在痛风性关节炎早期诊断的灵敏度和特异度分析[J]. 新医学, 2017, 48(6):403-405. |
[13] | Neuhaus V, Lennartz S, Abdullayev N, et al. Bone marrow edema in traumatic vertebral compression fractures: Diagnostic accuracy of dual-layer detector CT using calcium suppressed images[J]. Eur J Radiol, 2018, 105:216-220. |
[14] | Kosmala A, Weng AM, Krauss B, et al. Dual-energy CT of the bone marrow in multiple myeloma: diagnostic accuracy for quantitative differentiation of infiltration patterns[J]. Eur Radiol, 2018, 28(12):5083-5090. |
[15] | 袁伶俐, 徐斌, 张跃, 等. MRI 与关节镜对痛风性膝关节炎的诊断比较[J]. 中国现代医学杂志, 2018, 28(17):109-114. |
[16] | Mallinson PI, Coupal TM, McLaughlin PD, et al. Dual-Energy CT for the Musculoskeletal System[J]. Radiology, 2016, 281(3):690-707. |
[17] | 过永, 俞咏梅, 吴树剑, 等. 双能CT对痛风性关节炎的诊断价值[J]. 皖南医学院学报, 2018, 37(3):283-285. |
/
〈 |
|
〉 |