Journal of Tissue Engineering and Reconstructive Surgery ›› 2014, Vol. 10 ›› Issue (2): 89-91.doi: 10.3969/j.issn.1673-0364.2014.02.007

• Original article • Previous Articles     Next Articles

Clinical Application of Body-jet Hydrodynamic Liposuction System in Breast Augmentation with Autologous Fat Transplantation

ZUO Zongbao,SUN Jiaming,GUO Ke,GUO Nengqiang   

  1. Department of Plastic Surgery,Union Hospital of Tongji Medical College,Huazhong University of Science and Technology;
  • Published:2020-07-23

Abstract: Objective To explore the clinical application and postoperative effects of Body-jet hydrodynamic liposuction system in breast augmentation with autologous fat transplantation. Methods From September 2012 to December 2013, 18 cases received breast augmentation with autologous fat transplantation using Body-jet hydrodynamic liposuction system. The autologous fat was collected and purified by Body-jet hydrodynamic liposuction system, then was injected to each layer of breast tissue multi-levelly and multi-dimensionally. The fat dosage of unilateral breast injection ranged from 100-250 mL. Results After 6 to 12 months' follow-up, all 18 cases achieved good results including full-round contour, natural breast shape and soft feeling of palpation. Satisfactory outcome were received without severe complications. Conclusion Body-jet hydrodynamic liposuction technique is safe, effective, easy to operate, and is an ideal method for breast augmentation with autologous fat transplantation.

Key words: Autologous fat transplantation, Body-jet hydrodynamic liposuction system, Breast augmentation

CLC Number: